Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Clin Chim Acta ; 552: 117632, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37940015

RESUMO

BACKGROUND: Measurement of serum amino acid (AA) concentrations is important in particular for the diagnosis and monitoring of inborn errors of AA metabolism. To ensure optimal clinical interpretation of AAs, reliable biological variation (BV) data are essential. In the present study, we derived BV data for 22 non-essential, conditionally essential, and essential AAs and assessed differences in BV of AAs related to sex. METHODS: Morning blood samples were drawn from 66 subjects (31 males and 35 females) once a week for 10 consecutive weeks. All samples were analyzed in duplicate using liquid chromatography-tandem mass-spectrometry. The data were assessed for outliers, trends, normality and variance homogeneity analysis prior to estimating within-subject (CVI) and between-subject (CVG) BV. RESULTS: CVI estimates ranged from 9.0 % for histidine (male) to 33.0 % for taurine (male). CVI estimates in males and females were significantly different for all AAs except for aspartic acid, citrulline and phenylalanine, in most cases higher in females than in males. Apart from for arginine, CVG estimates in males and females were similar. CONCLUSIONS: In this highly powered BV study, we provide updated BV estimates for 22 AAs and demonstrate that for most AAs, CVI estimates differ between males and females, with implications for interpretation and use of AAs in clinical practice.


Assuntos
Aminoácidos , Caracteres Sexuais , Feminino , Humanos , Masculino , Aminoácidos/sangue
2.
Clin Chem Lab Med ; 61(2): 213-223, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36282875

RESUMO

Laboratories should estimate and validate [using analytical performance specifications (APS)] the measurement uncertainty (MU) of performed tests. It is therefore essential to appropriately define APS for MU, but also to provide a perspective on suitability of the practical application of these APS. In this study, 23 commonly ordered measurands were allocated to the models defined during the 2014 EFLM Strategic Conference to derive APS for MU. Then, we checked if the performance of commercial measuring systems used in our laboratory may achieve them. Most measurands (serum alkaline phosphatase, aspartate aminotransferase, creatine kinase, γ-glutamyltransferase, lactate dehydrogenase, pancreatic amylase, total proteins, immunoglobulin G, A, M, magnesium, urate, and prostate-specific antigen, plasma homocysteine, and blood red and white cells) were allocated to the biological variation (BV) model and desirable APS were defined accordingly (2.65%, 4.75%, 7.25%, 4.45%, 2.60%, 3.15%, 1.30%, 2.20%, 2.50%, 2.95%, 1.44%, 4.16%, 3.40%, 3.52%, 1.55%, and 5.65%, respectively). Desirable APS for serum total cholesterol (3.00%) and urine albumin (9.00%) were derived using outcome-based model. Lacking outcome-based information, serum albumin, high-density lipoprotein cholesterol, triglycerides, and blood platelets were temporarily reallocated to BV model, the corresponding desirable APS being 1.25%, 2.84%, 9.90%, and 4.85%, respectively. A mix between the two previous models was employed for serum digoxin, with a 6.00% desirable APS. In daily practice by using our laboratory systems, 16 tests fulfilled desirable and five minimum APS, while two (serum albumin and plasma homocysteine) exceeded goals, needing improvements.


Assuntos
Laboratórios , Albumina Sérica , Masculino , Humanos , Incerteza , Colesterol , Homocisteína
3.
Clin Chem ; 68(9): 1202-1210, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35794075

RESUMO

BACKGROUND: Serum ferritin is considered a suitable biomarker of iron-related disorders. However, data about the comparability of results among commercial measuring systems (MSs) are contradictory. We performed an intercomparison study aimed at verifying the current interassay variability and its impact on clinical application of the test. Obtaining this information is vital because manufacturers continue to claim calibration alignment to different WHO preparations, which are not related to each other in terms of traceability. METHODS: Four widely used MSs were evaluated. The interassay agreement was verified using 39 human serum pools. The recovery of WHO International Standard (IS) 94/572 (the only reference material available at the time of the study) was evaluated, after assessing the material commutability. Finally, an approach for harmonizing ferritin results was proposed. RESULTS: Highly significant differences (P < 0.00001) among ferritin concentrations assayed by different MSs were detected and the interassay CV (median 22.9%; interquartile range 21.8-25.5) overlapped the desirable intermethod bias (24.6%). IS 94/572 was commutable for use only with Access and Centaur, with Access being the only MS correctly recovering its assigned value. Accordingly, we used regression data against Access to recalibrate MSs, indirectly aligning them to IS 94/572, with a substantial improvement in degree of harmonization and traceability to higher-order reference. CONCLUSIONS: The harmonization among evaluated ferritin MSs is far from optimal, with the implementation of traceability to different WHO ISs being a factor of confusion. A recalibration approach, however, would permit measurement harmonization, allowing the use of common decision thresholds.


Assuntos
Ferritinas , Ferro , Biomarcadores , Calibragem , Humanos , Padrões de Referência
5.
Clin Chem Lab Med ; 60(4): 494-504, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35143717

RESUMO

OBJECTIVES: Biological variation data (BV) can be used for different applications, but this depends on the availability of robust and relevant BV data. In this study, we aimed to summarize and appraise BV studies for tumor markers, to examine the influence of study population characteristics and concentrations on BV estimates and to discuss the applicability of BV data for tumor markers in clinical practice. METHODS: Studies reporting BV data for tumor markers related to gastrointestinal, prostate, breast, ovarian, haematological, lung, and dermatological cancers were identified by a systematic literature search. Relevant studies were evaluated by the Biological Variation Data Critical Appraisal Checklist (BIVAC) and meta-analyses were performed for BIVAC compliant studies to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV with 95% CI. RESULTS: The systematic review identified 49 studies delivering results for 22 tumor markers; four papers received BIVAC grade A, 3 B, 27 C and 15 D. Out of these, 29 CVI and 29 CVG estimates met the criteria to be included in the meta-analysis. Robust data are lacking to conclude on the relationship between BV and different disease states and tumor marker concentrations. CONCLUSIONS: This review identifies a lack of high-quality BV studies for many tumor markers and a need for delivery of BIVAC compliant studies, including in different disease states and tumor marker concentrations. As of yet, the state-of-the-art may still be the most appropriate model to establish analytical performance specifications for the majority of tumor markers.


Assuntos
Biomarcadores Tumorais , Lista de Checagem , Humanos , Masculino
6.
Sci Total Environ ; 817: 153002, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35031364

RESUMO

COVID-19 lockdown brought to a drastic reduction of anthropic impacts on the environment worldwide, including the marine-coastal system. Earth-Observation (EO) data have the potential to monitor and diagnose the effects of the lockdown in terms of water quality. Here we connect the dots among some coastal environmental changes that occurred during the Italian COVID-19 lockdown by using EO data, also seeking to assess connectivity between inland and marine systems. We present a holistic analysis of spatial and temporal variability of environmental parameters in the North Adriatic Sea, Mediterranean basin, exploiting the synergy of different satellite sensors, as well as hydrologic data from in situ observations. Our analysis indicates a favourable interplay of environmental variability that resulted in negative anomalies of Chlorophyll-a concentration, with respect to the climatologic values. Peculiar meteo-oceanographic and hydrological conditions made hard to disentangle potential anthropogenic effects. However, a multi-year hierarchical cluster analysis of riverine remote sensing reflectances groups together the optical properties of inland waters during the lockdown. This emergent cluster highlights the possibility of a second-order, anthropogenic effect that, superimposed to the (first-order) environmental natural causes, may have enhanced water quality during the lockdown.


Assuntos
COVID-19 , COVID-19/epidemiologia , Clorofila A , Controle de Doenças Transmissíveis , Monitoramento Ambiental/métodos , Humanos , Percepção , SARS-CoV-2
7.
Clin Chem Lab Med ; 60(4): 483-493, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-34773727

RESUMO

OBJECTIVES: Testing for thyroid disease constitutes a high proportion of the workloads of clinical laboratories worldwide. The setting of analytical performance specifications (APS) for testing methods and aiding clinical interpretation of test results requires biological variation (BV) data. A critical review of published BV studies of thyroid disease related measurands has therefore been undertaken and meta-analysis applied to deliver robust BV estimates. METHODS: A systematic literature search was conducted for BV studies of thyroid related analytes. BV data from studies compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) were subjected to meta-analysis. Global estimates of within subject variation (CVI) enabled determination of APS (imprecision and bias), indices of individuality, and indicative estimates of reference change values. RESULTS: The systematic review identified 17 relevant BV studies. Only one study (EuBIVAS) achieved a BIVAC grade of A. Methodological and statistical issues were the reason for B and C scores. The meta-analysis derived CVI generally delivered lower APS for imprecision than the mean CVA of the studies included in this systematic review. CONCLUSIONS: Systematic review and meta-analysis of studies of BV of thyroid disease biomarkers have enabled delivery of well characterized estimates of BV for some, but not all measurands. The newly derived APS for imprecision for both free thyroxine and triiodothyronine may be considered challenging. The high degree of individuality identified for thyroid related measurands reinforces the importance of RCVs. Generation of BV data applicable to multiple scenarios may require definition using "big data" instead of the demanding experimental approach.


Assuntos
Lista de Checagem , Glândula Tireoide , Biomarcadores , Testes Hematológicos , Humanos , Valores de Referência
8.
Clin Chem Lab Med ; 60(4): 469-478, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-32970605

RESUMO

OBJECTIVES: Kidney markers are some of the most frequently used laboratory tests in patient care, and correct clinical decision making depends upon knowledge and correct application of biological variation (BV) data. The aim of this study was to review available BV data and to provide updated BV estimates for the following kidney markers in serum and plasma; albumin, creatinine, cystatin C, chloride, potassium, sodium and urea. CONTENT: Relevant studies were identified from a historical BV database as well as by systematic literature searches. Retrieved publications were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC compliant studies with similar design were performed to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV estimates. Out of the 61 identified papers, three received a BIVAC grade A, four grade B, 48 grade C, five grade D grade and one was not appraised as it did not report numerical BV estimates. Most studies were identified for creatinine (n=48). BV estimates derived from the meta-analysis were in general lower than previously reported estimates for all analytes except urea. For some measurands, BV estimates may be influenced by age or states of health, but further data are required. SUMMARY: This review provides updated global BV estimates for kidney related measurands. For all measurands except for urea, these estimates were lower than previously reported. OUTLOOK: For the measurands analyzed in this review, there are sufficient well-designed studies available to publish a trustworthy estimate of BV. However, for a number of newly appearing kidney markers no suitable data is available and additional studies are required.


Assuntos
Rim , Ureia , Biomarcadores , Creatinina , Humanos
10.
Clin Chem ; 67(12): 1590-1605, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34633037

RESUMO

BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community. CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined. SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy.


Assuntos
Laboratórios , Calibragem , Bases de Dados Factuais , Humanos , Padrões de Referência , Incerteza
11.
Clin Chem Lab Med ; 59(8): 1400-1408, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33831978

RESUMO

OBJECTIVES: Idiopathic pulmonary fibrosis (IPF) is a progressive interstitial disease with limited therapeutic options. The measurement of Krebs von den Lungen-6 (KL-6) glycoprotein has been proposed for evaluating the risk of IPF progression and predicting patient prognosis, but the robustness of available evidence is unclear. METHODS: We searched Medline and Embase databases for peer-reviewed literature from inception to April 2020. Original articles investigating KL-6 as prognostic marker for IPF were retrieved. Considered outcomes were the risk of developing acute exacerbation (AE) and patient survival. Meta-analysis of selected studies was conducted, and quantitative data were uniformed as odds ratio (OR) or hazard ratio (HR) estimates, with corresponding 95% confidence intervals (CI). RESULTS: Twenty-six studies were included in the systematic review and 14 were finally meta-analysed. For AE development, the pooled OR (seven studies) for KL-6 was 2.72 (CI 1.22-6.06; p=0.015). However, a high degree of heterogeneity (I2=85.6%) was found among selected studies. Using data from three studies reporting binary data, a pooled sensitivity of 72% (CI 60-82%) and a specificity of 60% (CI 52-68%) were found for KL-6 measurement in detecting insurgence of AE in IPF patients. Pooled HR (seven studies) for mortality prediction was 1.009 (CI 0.983-1.036; p=0.505). CONCLUSIONS: Although our meta-analysis suggested that IPF patients with increased KL-6 concentrations had a significant increased risk of developing AE, the detection power of the evaluated biomarker is limited. Furthermore, no relationship between biomarker concentrations and mortality was found. Caution is also needed when extending obtained results to non-Asian populations.


Assuntos
Fibrose Pulmonar Idiopática , Biomarcadores , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Mucina-1 , Razão de Chances , Prognóstico , Modelos de Riscos Proporcionais
12.
Clin Chem ; 67(3): 543-553, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33674839

RESUMO

BACKGROUND: Previous studies have shown that the harmonization of prostate-specific antigen (PSA) assays remained limited even after the introduction of WHO International Standards. This information needs updating for current measuring systems (MS) and reevaluation according to established analytical performance specifications (APS) and the characteristics of antibodies used. METHODS: Total (tPSA) and free (fPSA) PSA were measured in 135 and 137 native serum samples, respectively, by Abbott Alinity i, Beckman Access Dxl, Roche Cobas e801, and Siemens Atellica IM MSs. Passing-Bablok regression and difference plots were used to compare results from each MS to the all-method median values. Agreement among methods was evaluated against APS for bias derived from biological variation of the 2 measurands. RESULTS: The median interassay CV for tPSA MSs (11.5%; 25-75th percentiles, 9.2-13.4) fulfilled the minimum APS goal for intermethod bias (15.9%), while the interassay CV for fPSA did not [20.4% (25-75th percentiles, 18.4-22.7) vs goal 17.6%]. Considering the all-method median value of each sample as reference, all tPSA MSs exhibited a mean percentage bias within the minimum goal. On the other hand, Alinity (+21.3%) and Access (-24.2%) were out of the minimum bias goal for fPSA, the disagreement explained only in minimal part by the heterogeneity of employed antibodies. CONCLUSIONS: The harmonization among tPSA MSs is acceptable only when minimum APS are applied and necessitates further improvement. The marked disagreement among fPSA MSs questions the use of fPSA as a second-level test for biopsy referral.


Assuntos
Tomada de Decisão Clínica , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia
13.
Clin Chem Lab Med ; 2021 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-33725754

RESUMO

OBJECTIVES: Definition and fullfillment of analytical performance specifications (APS) for measurement uncertainty (MU) allow to make laboratory determinations clinically usable. The 2014 Milan Strategic Conference have proposed models to objectively derive APS based on: (a) the effect of analytical performance on clinical outcome; (b) biological variation components; and (3) the state of the art of the measurement, defined as the highest level of analytical performance technically achievable. Using these models appropriately, we present here a proposal for defining APS for standard MU for some common biochemical measurands. METHODS: We allocated a group of 13 measurands selected among the most commonly laboratory requested tests to each of the three Milan models on the basis of their biological and clinical characteristics. Both minimum and desirable levels of quality of APS for standard MU of clinical samples were defined by using information obtained from available studies. RESULTS: Blood total hemoglobin, plasma glucose, blood glycated hemoglobin, and serum 25-hydroxyvitamin D3 were allocated to the model 1 and the corresponding desirable APS were 2.80, 2.00, 3.00, and 10.0%, respectively. Plasma potassium, sodium, chloride, total calcium, alanine aminotransferase, creatinine, urea, and total bilirubin were allocated to the model 2 and the corresponding desirable APS were 1.96, 0.27, 0.49, 0.91, 4.65, 2.20, 7.05, and 10.5%, respectively. For C-reactive protein, allocated to the model 3, a desirable MU of 3.76% was defined. CONCLUSIONS: APS for MU of clinical samples derived in this study are essential to objectively evaluate the reliability of results provided by medical laboratories.

15.
Clin Chem ; 67(1): 256-264, 2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33279972

RESUMO

BACKGROUND: Many studies have assessed the biological variation (BV) of cardiac-specific troponins (cTn), reporting widely varying within-subject BV (CVI) estimates. The aim of this study was to provide meta-analysis-derived BV estimates for troponin I (cTnI) and troponin T (cTnT) for different sampling intervals and states of health. METHODS: Relevant studies were identified by a systematic literature search. Studies were classified according to their methodological quality by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC-compliant studies were performed after stratification by cTn isoform, exclusion of results below the limit of detection, states of health, and sampling interval to deliver reference change values (RCV), index of individuality (II) and analytical performance specifications (APS) for these settings. RESULTS: Sixteen and 15 studies were identified for cTnI and cTnT, respectively, out of which 6 received a BIVAC grade A. Five studies had applied contemporary cTnI assays, but none contemporary cTnT. High-sensitivity (hs-) cTnI and cTnT delivered similar estimates in all settings. Long-term CVI estimates (15.1; 11.3%) derived from healthy individuals were higher than short-term (4.3%; 5.3%) for hs-cTnI and hs-cTnT, respectively, although confidence intervals overlapped. Estimates derived from diseased subjects were similar to estimates in healthy individuals for all settings. CONCLUSIONS: This study provides robust estimates for hs-cTnI and hs-cTnT applicable for different clinical settings and states of health, allowing for the use of RCV both to aid in the diagnosis of myocardial injury and for prognosis. BV-based APS appear too strict for some currently available technologies.


Assuntos
Doenças Cardiovasculares/diagnóstico , Nefropatias/diagnóstico , Troponina I/análise , Troponina T/análise , Variação Biológica Individual , Biomarcadores/análise , Humanos , Prognóstico , Valores de Referência , Troponina I/normas , Troponina T/normas
16.
Sensors (Basel) ; 20(16)2020 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-32823847

RESUMO

This study presents a first assessment of the Top-Of-Atmosphere (TOA) radiances measured in the visible and near-infrared (VNIR) wavelengths from PRISMA (PRecursore IperSpettrale della Missione Applicativa), the new hyperspectral satellite sensor of the Italian Space Agency in orbit since March 2019. In particular, the radiometrically calibrated PRISMA Level 1 TOA radiances were compared to the TOA radiances simulated with a radiative transfer code, starting from in situ measurements of water reflectance. In situ data were obtained from a set of fixed position autonomous radiometers covering a wide range of water types, encompassing coastal and inland waters. A total of nine match-ups between PRISMA and in situ measurements distributed from July 2019 to June 2020 were analysed. Recognising the role of Sentinel-2 for inland and coastal waters applications, the TOA radiances measured from concurrent Sentinel-2 observations were added to the comparison. The results overall demonstrated that PRISMA VNIR sensor is providing TOA radiances with the same magnitude and shape of those in situ simulated (spectral angle difference, SA, between 0.80 and 3.39; root mean square difference, RMSD, between 0.98 and 4.76 [mW m-2 sr-1 nm-1]), with slightly larger differences at shorter wavelengths. The PRISMA TOA radiances were also found very similar to Sentinel-2 data (RMSD < 3.78 [mW m-2 sr-1 nm-1]), and encourage a synergic use of both sensors for aquatic applications. Further analyses with a higher number of match-ups between PRISMA, in situ and Sentinel-2 data are however recommended to fully characterize the on-orbit calibration of PRISMA for its exploitation in aquatic ecosystem mapping.

17.
Clin Chem Lab Med ; 59(2): 291-300, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32639119

RESUMO

To be accurate and equivalent, laboratory results should be traceable to higher-order references. Furthermore, their quality should fulfill acceptable measurement uncertainty (MU) as defined to fit the intended clinical use. With this aim, in vitro diagnostics (IVD) manufacturers should define a calibration hierarchy to assign traceable values to their system calibrators. Medical laboratories should know and verify how manufacturers have implemented the traceability of their calibrators and estimate the corresponding MU on clinical samples. Accordingly, the internal quality control (IQC) program should be redesigned to permit IVD traceability surveillance through the verification by medical laboratories that control materials, provided by the manufacturer as a part of measuring systems, are in the clinically suitable validation range (IQC component I). Separately, laboratories should also monitor the reliability of employed IVD measuring systems through the IQC component II, devoted to estimation of MU due to random effects and to obtaining MU of provided results, in order to apply prompt corrective actions if the performance is worsening when compared to appropriate analytical specifications, thus jeopardizing the clinical validity of test results.


Assuntos
Controle de Qualidade , Calibragem , Técnicas de Laboratório Clínico , Técnicas e Procedimentos Diagnósticos , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Incerteza
19.
Sci Total Environ ; 736: 139612, 2020 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-32470688

RESUMO

The lagoon of Venice has always been affected by the regional geomorphological evolution, anthropogenic stressors and global changes. Different morphological settings and variable biogeophysical conditions characterize this continuously evolving system that rapidly responds to the anthropic impacts. When the lockdown measures were enforced in Italy to control the spread of the SARS-CoV-2 infection on March 10th 2020, the ordinary urban water traffic around Venice, one of the major pressures in the lagoon, came to a halt. This provided a unique opportunity to analyse the environmental effects of restrictions to mobility on water transparency. Pseudo true-colour composites Sentinel-2 satellite imagery proved useful for qualitative visual interpretation, showing the reduction of the vessel traffic and their wakes from the periods before and during the SARS-CoV-2 outbreak. A quantitative analysis of suspended matter patterns, based on satellite-derived turbidity, in the absence of traffic perturbations, allowed to focus on natural processes and the residual stress from human activities that continued throughout the lockdown. We conclude that the high water transparency can be considered as a transient condition determined by a combination of natural seasonal factors and the effects of COVID-19 restrictions.


Assuntos
Infecções por Coronavirus , Monitoramento Ambiental , Pandemias , Pneumonia Viral , Qualidade da Água , Betacoronavirus , COVID-19 , Atividades Humanas , Humanos , Itália , Nefelometria e Turbidimetria , SARS-CoV-2 , Imagens de Satélites
20.
Clin Chem ; 66(5): 667-675, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32353141

RESUMO

BACKGROUND: The measurement of neuron-specific enolase (NSE) in serum is frequently requested for diagnosis, risk stratification, and treatment monitoring of neuroblastoma (NB) in the pediatric population. However, authoritative clinical practice guidelines advise about the poor diagnostic performance of NSE. CONTENT: We critically appraised the available literature evaluating the diagnostic and prognostic value of NSE in the management of NB, paying special attention to the definition of appropriate threshold levels. In addition, we discuss the interfering conditions causing artifactual increases of NSE concentrations in serum and potentially influencing the clinical evaluation of patients with suspected NB. SUMMARY: No definitive evidence supports the use of serum NSE for diagnosis and monitoring of NB. The risk of obtaining false-positive NSE results associated with confounders (e.g., sample hemolysis) and other pathophysiologic conditions (e.g., inflammation) is remarkable and hampers the diagnostic value of this test. NSE may be helpful to define the risk of death of patients with NB, mainly in the advanced stages of disease. However, further studies validating currently marketed immunoassays and defining threshold values useful for this scope are warranted.


Assuntos
Biomarcadores Tumorais , Neuroblastoma , Criança , Humanos , Neuroblastoma/diagnóstico , Neuroblastoma/terapia , Fosfopiruvato Hidratase , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...